Accession Number : ADA123768


Title :   High Performance Split-Stirling Cooler Program


Descriptive Note : Final technical rept. Sep 79-Sep 82


Corporate Author : CTI-CRYOGENICS WALTHAM MA


Personal Author(s) : Meeker, Richard P


Full Text : http://www.dtic.mil/dtic/tr/fulltext/u2/a123768.pdf


Report Date : Sep 1982


Pagination or Media Count : 114


Abstract : This report describes the physical characteristics of the final design configuration of the 1 Watt Split-Stirling Cryogenic Cooler. Qualification testing included evaluation of the 1.0 Watt Cryogenic Cooler under the following conditions: Performance tests over the temperature range of -40 degrees C to +55 degrees C; High and Low Temperature Shock Tests; Mechanical Shock Tests; Sinsoidal Vibration; Self-Induced Vibration; Acoustical Testing; and 1000-Hour Mean Time Between Failure Life Tests. The cryogenic cooler design consists of a motor and compressor assembly, and a remote expander assembly, interconnected by a stainless steel capillary line. The system is nominally a 18.5 VDC, 60 Watt cooler and has a maximum weight of 4 pounds. This report summarizes the results of the performance, environmental and life qualification tests conducted under the contract and provides supporting data for each of the test categories. (Author)


Descriptors :   *CRYOGENICS , *REFRIGERATION SYSTEMS , *STIRLING CYCLE , LOW TEMPERATURE , MECHANICAL PROPERTIES , VIBRATION , SYSTEMS ENGINEERING , ELECTROOPTICS , PERFORMANCE(ENGINEERING) , HIGH TEMPERATURE , FAILURE , TEST METHODS , ACOUSTICS , ENVIRONMENTAL TESTS , SHOCK TESTS