Accession Number : AD0770603


Title :   Real-Time Display of Radiation Field Intensity Distribution,


Descriptive Note : Technical note,


Corporate Author : ARMED FORCES RADIOBIOLOGY RESEARCH INST BETHESDA MD


Personal Author(s) : Berardo,P. A. ; Willis,J. A.


Report Date : AUG 1973


Pagination or Media Count : 22


Abstract : A real-time display system has been designed and tested for use with a radiation field monitor. The system uses only pulse and wave-form generators, a multiplexer and an oscilloscope. The display consits of either a three-dimensional representation of the field intensity distribution or a series of simultaneous profiles. (Author)


Descriptors :   *Linear accelerators, *Radiation measuring instruments, Cathode ray tube screens, Real time, Signal processing, Multiplexing


Subject Categories : NUCLEAR INSTRUMENTATION


Distribution Statement : APPROVED FOR PUBLIC RELEASE